Specifications
- Power supply, control and protection of DC lifting solenoids when operating from the AC power supply system
- Electromagnets
- Crane equipment
A glance at the most important advantages
-
Ensuring safety during operation
-
Early signaling power supply problems.
-
Monitoring the power supply
-
Protection against short circuits
Key features and functions
DIMET ПН-500 voltage transformers are designed for power supply, control and protection of load-bearing DC-electromagnets. Thanks to the high IP55 protection rating, they can be used in dusty environments
Key features and functions:
- Boost mode for the rapid increase of the current flowing in the electromagnets
- Demagnetization mode
- Display indicating the operating mode and fault conditions
- Stepless current control
- Limitation of maximum output voltage to 220-230 V
- Load short circuit protection
- Cross-circuit and ground fault protection
- Alarm in case of cable break
- Alarm for exceeding the leakage current in the electromagnet circuit (in case of overheating of the electromagnet)
- Alarm for short circuit between the electromagnet windings
- Alarm when the maximum allowed current is exceeded
- Limitation for the maximum output current
Technical specification
Metric system of measurement
Parameters |
PN-500-3-100A |
PN-500-3-150A |
PN-500-3-200A |
PN-500-3-250A |
Power supply |
three-phase |
three-phase |
three-phase |
three-phase |
Supply voltage, V |
380+60 |
380±60 |
380±60 |
380+60 |
Frequency, Hz |
50 |
50 |
50 |
50 |
Output voltage regulation range, V |
10-230 |
10-230 |
60-230 |
60-230 |
Demagnetizing time, at most, s |
3 |
3 |
5 |
5 |
Duty cycle, % |
75, 100 |
75, 100 |
75, 100 |
75, 100 |
Maximum permissible current at duty cycle – 75%, А |
100 |
150 |
200 |
250 |
Maximum permissible current at duty cycle – 100%, A |
50 |
80 |
110 |
125 |
Overall dimensions, mm |
360х150х375 |
360х150х375 |
450х200х375 |
450х200х375 |
Coupling sizes, mm |
255х350 |
255х350 |
255х350 |
255х350 |
Weight, at most, kg |
12,2 |
12,5 |
16 |
17 |
Imperial and US customary systems
Parameters |
PN-500-3-100A |
PN-500-3-150A |
PN-500-3-200A |
PN-500-3-250A |
Power supply |
three-phase |
three-phase |
three-phase |
three-phase |
Supply voltage, V |
380±60 |
380±60 |
380±60 |
380±60 |
Frequency, Hz |
50 |
50 |
50 |
50 |
Output voltage regulation range, V |
10-230 |
10-230 |
60-230 |
60-230 |
Demagnetizing time, at most, sec |
3 |
3 |
5 |
5 |
Duty cycle, % |
75 |
75 |
75 |
75 |
Maximum permissible current at duty cycle – 75%, А |
100 |
150 |
200 |
250 |
Overall dimensions, in |
14x6x14 |
14x6x14 |
17x7x14 |
17x7x14 |
Coupling sizes, in |
10x13 |
10x13 |
10x13 |
10x13 |
Weight, at most, lbs |
26 |
27 |
35 |
37 |